Table 2-2 – Windy Nation Xantrex C Series Multifunction DC Controller User Manual

Page 55

Advertising
background image

Temperature Compensation

975-0004-01-02 Rev D

35

Table 2-2 Variances in Charging Voltage based on Battery Temperature

Temperature

(around the BTS)

12-volt units

24-volt units

48-volt units

Celsius Fahrenheit

Lead

Acid

(6 cells)

NiCad

(10 cells)

Lead

Acid

(12 cells)

NiCad

(20 cells)

Lead

Acid

(24 cells)

NiCad

(40 cells)

60

140

-1.05

-0.70

-2.10

-1.40

-4.20

-2.80

55

131

-0.90

-0.60

-1.80

-1.20

-3.60

-2.40

50

122

-0.75

-0.50

-1.50

-1.00

-3.00

-2.00

45

113

-0.60

-0.40

-1.20

-0.80

-2.40

-1.60

40

104

-0.45

-0.30

-0.90

-0.60

-1.80

-1.20

35

95

-0.30

-0.20

-0.60

-0.40

-1.20

-0.80

30

86

-0.15

-0.10

-0.30

-0.20

-0.60

-0.40

25

77

0.00

0.00

0.00

0.00

0.00

0.00

20

68

0.15

0.10

0.30

0.20

0.60

0.40

15

59

0.30

0.20

0.60

0.40

1.20

0.80

10

50

0.45

0.30

0.90

0.60

1.80

1.20

5

41

0.60

0.40

1.20

0.80

2.40

1.60

0

32

0.75

0.50

1.50

1.00

3.00

2.00

-5

23

0.90

0.60

1.80

1.20

3.60

2.40

-10

14

1.05

1.20

2.10

1.40

4.20

2.80

-15

5

1.20

0.80

2.40

1.60

4.80

3.20

-20

-4

1.35

1.40

2.70

1.80

5.40

3.60

-25

-13

1.50

1.00

3.00

2.00

6.00

4.00

-30

-22

1.65

1.10

3.30

2.20

6.60

4.40

-35

-31

1.80

1.20

3.60

2.40

7.20

4.80

-40

-40

1.95

1.30

3.90

2.60

7.80

5.20

Advertising