Features and Options Specifications

975-0004-01-02 Rev D

71

Features and Options Specifications

The following lists the features and options specifications for
the

C-Series controller

s Models C35, C40, and C60.

Load Control Settings:

System Voltage:

Low Voltage
Reconnect
Low Voltage
Disconnect

12 Volt System:

LVR 12.0 to 14.0 Vdc

LVD 10.5 to 12.5 Vdc

24 Volt System:

LVR 24.0 to 28.0 Vdc

LVD 21.0 to 25.0 Vdc

48 Volt System:

LVR 48.0 to 56.0 Vdc

LVD 42.0 to 50.0 Vdc

Table A-2 Features and Options Specifications

Model

C35

C40

C60

Standard Features

Status Indicator

Multi color LED indicates the operating/battery voltage status.

Low Voltage Disconnect
Load Control Mode

User selectable manual or automatic reconnection - includes warning
flash before disconnect and 6 minutes “grace” period.

Equalization Charge
Charge Control Mode

User selectable manual or automatic equalization (every 30 days).

Short Circuit Protection

Fully electronically protected with auto-reset.

Adjustable Control
Setpoints (test points
provided for high
accuracy

Two user-adjustable, voltage setpoints for control of loads or charging
sources (settings retained if battery is disconnected.)

Options

LCD Meter Panel
(CM, CM/R-50,
CM/R-100)

Back-lit, 32-character, alpha-numeric liquid crystal display panel for
remote (CM/R) or front mounting (CM) on the C-Series controller.

External Battery
Temperature Sensor
(BTS/15, BTS/35)

Provides automatic adjustment of the charge control set point to the
battery temperature (may be extended)

Table A-1 Electrical Specifications