Operating mode jumper, Voltage jumper, Operating mode jumper voltage jumper – Windy Nation Xantrex C Series Multifunction DC Controller User Manual

Page 40: Figure 2-6, Mode of operation jumper, Figure 2-7, Voltage selection jumper

Advertising
background image

Installation

20

975-0004-01-02 Rev D

Operating Mode Jumper

This jumper determines the operating mode. Place the jumper
over the pins that correspond to the desired mode.

Charge Control (PV Charge Controller or Diversion
Controller)

Load Control (Load Controller)

Factory default setting is Charge Control mode.

Voltage Jumper

The voltage jumper determines the voltage of the system that
the controller will be used with. To set the voltage, place the
jumper over the two pins adjacent to the legend for the
voltage of your system: 12, 24, 48. Factory setting is 12 volts
for the C35, C40, and C60.

Figure 2-6 Mode of Operation Jumper

Figure 2-7 Voltage Selection Jumper

Charge/Load
Control
Jumper

Charge Control Mode

Load Control Mode

12 Volt Position

24 Volt Position

48 Volt Position

12 Volt Position

24 Volt Position

C40 Models

C35 and C60
Models