The scale for the Low Voltage Disconnect setting is
calibrated as follows:

12-volt system: 10.5 to 12.5 volts
in increments of 0.2 volts,

24-volt system: 21.0 to 25.0 volts
in increments of 0.4 volts, and

48-volt system: 42.0 to 50.0 volts
in increments of 0.8 volts.

Figure 2-12 LVR and LVD Settings for Load Control Mode