Dc load control mode wiring – Windy Nation Xantrex C Series Multifunction DC Controller User Manual

Page 68

Advertising
background image

Installation

48

975-0004-01-02 Rev D

DC Load Control Mode Wiring

The procedure below is illustrated in

Figure 2-25

.

To connect the C-Series controller as a DC load
controller:

1.

Connect a cable from the

BAT

POSITIVE

terminal on the

controller to a battery disconnect.

2.

Connect the positive battery cable to the battery
disconnect.

3.

Connect the negative battery cable to the one of the
terminals marked

COMMON

NEGATIVES

.

4.

Connect a cable between the

PV

POS

/

LOAD

terminal on

the controller and the positive terminal on the DC load.

5.

Connect a cable between the controller’s other

COMMON

NEGATIVES

terminal and to the negative terminal of the

load.

6.

Tighten per torque requirements outlined on

page 39

.

Allow a little slack on the cables within the controller and
secure the wiring with strain reliefs.

Advertising