Equalization setpoints (non-sealed batteries only), Table b-1, Typical bulk and float setpoints for batteries – Windy Nation Xantrex C Series Multifunction DC Controller User Manual

Page 99

Advertising
background image

Equalization Charging

975-0004-01-02 Rev D

79

Equalization Setpoints (Non-Sealed Batteries Only)

Table B-1 Typical Bulk and Float Setpoints for Batteries

Battery Type

Bulk Volts

Float Volts

Equalizing
Charge

Default Settings (knobs
at nine o’clock position)

14.0 Vdc

13.5 Vdc

Disabled
(manual
jumper)

Sealed Gel Lead Acid
Battery

14.1 Vdc

13.6 Vdc

Non
recommended.
Consult Battery
manufacturer.

AGM Lead Acid
Battery

14.4 Vdc

13.4 Vdc

Charge to
15.5 Vdc or per
manufacturer.

Maintenance-Free
RV/Marine

14.4 Vdc

13.4 Vdc

Limited
appropriateness
- if water level
can be checked.

Deep-Cycle, Liquid
Electrolyte Lead
Antimony Battery

14.6 Vdc

13.4 Vdc

Charge to
15.5 Vdc or per
battery
manufacturer.

NiCad or NiFe Alkaline

Battery

a

a.For NiCad and NiFe batteries, you must clip the R46 resistor and add 2 volts to the values
for BULK AND FLOAT shown on the circuit board. For example, set the BULK for
16.0 V adjust the BULK knob to 14.0 V after clipping R46. Values above are for batteries
at room temperature. For applications with significant temperature variations or systems
with sealed batteries, install a battery temperature sensor.

16.0 Vdc

14.5 Vdc

Not
recommended.
Consult battery
manufacturer.

Values shown are for 12-volt systems. For 24-volt Systems, multiply this
setting shown by 2. For 48-volt systems, multiply the settings shown by 4.

Important: The following settings (Table B-1) are guidelines only. Refer to
your battery vendor for specific settings and battery maintenance guidelines.

Advertising