Count, Pc.opt, Mmode – Holtgreven Ohaus Defender Series Bench Scales User Manual

Page 29: Percnt, Dynamm, Level, Check

Advertising
background image

7000 Series Indicators EN-27

COUNt

PC AUTO OPT

ON

PC.OPt

OFF

mMOdE

PERCENT

ON

PErCNt

OFF

mMOdE

DYNAMIC

AUTO

SEMI AUTO

MANUAL

dYNAmM

OFF

60

LEVEL

0

mMOdE

CHECKWEIGH

PCS

WEIGH

CHECK

OFF

mMOdE

END MODE

3.6.4 Parts Counting Optimization
When the Parts Counting mode is turned ON, Parts Counting Optimization can be used to
automatically adjust the average piece weight (APW). Each time a quantity greater than 1x or less
then 3x the previous quantity is placed on the scale, the APW is adjusted.

OFF

=

disabled

ON

=

enabled



3.6.5 Percent Weighing Mode
Set the status.

OFF

=

disabled

ON

=

enabled





3.6.6 Dynamic Weighing Mode
Set the status.

OFF =

disabled

MANUAL

= averaging and resetting are manually initiated by pressing the
FUNCTION button.

SEMI AUTO

= averaging is automatically initiated when the display exceeds 5
graduations; resetting is manually initiated by pressing the

FUNCTION

button.

AUTO

= averaging is automatically initiated when the display exceeds 5
graduations; resetting is automatically initiated when the display returns
to within 5 graduations of zero.


If MANUAL, SEMI AUTO, or AUTO is selected, the current averaging time is displayed.


Set the averaging time.

Settings of 0 to 60 seconds are available.

NOTE: Select 0 seconds to enable the Display Hold function. In this case, the first stable weight will

be held on the display.

3.6.7 Check Weighing Mode
Set the status.

OFF

=

disabled

WEIGH

= enabled for checking items by weight.

PCS

= enabled for checking items by count.




3.6.8 End Mode
Advance to the next menu or return to the top of the current menu.


Advertising