L.mmenu, L.prt1, L.prt2 – Holtgreven Ohaus Defender Series Bench Scales User Manual

Page 43: L.gmmp, L.i-o

Advertising
background image

7000 Series Indicators EN-41

L.mMENU

LOCK PRINT1

ON

L.Prt1

OFF

L.mMENU

LOCK PRINT2

ON

L.Prt2

OFF

L.mMENU

LOCK COM1

ON

L.COmM1

OFF

L.mMENU

LOCK COM2

ON

L.COmM2

OFF

L.mMENU

LOCK GMP

ON

L.GmMp

OFF

L.mMENU

LOCK I-O

ON

L.I-O

OFF

L.mMENU

END MENULOCK

3.12.7 Lock Print1
Set the status.

OFF

= the Print1 menu is not locked.

ON

= the Print1 menu is locked.




3.12.8 Lock Print2
Set the status.

OFF

= the Print2 menu is not locked.

ON

= the Print2 menu is locked.




3.12.9 Lock COM1
Set the status.

OFF

= the COM1 menu is not locked.

ON

= the COM1 menu is locked.




3.12.10 Lock COM2
Set the status.

OFF

= the COM2 menu is not locked.

ON

= the COM2 menu is locked.




3.12.11 Lock GMP
Set the status.

OFF

= the GMP menu is not locked.

ON

= the GMP menu is locked.




3.12.12 Lock I-O
Set the status.

OFF

= the I-O menu is not locked.

ON

= the I-O menu is locked.




3.12.13 End Menu Lock
Advance to the next menu or return to the top of the current menu.