Print1, Inter, A.print – Holtgreven Ohaus Defender Series Bench Scales User Manual

Page 34: Result, Contnt, Gross, On.stab

Advertising
background image

EN-32 7000 Series Indicators

CONTINUOUS

ACCEPT

INTERVAL

PrINt1

AUTO PRINT

3600

PrINt1

CONTENT

ON STABLE

NUMERIC ONLY

ON

ON

ON

LOAD ZERO

3.9.3 Auto Print
Set the automatic printing functionality.

OFF =

disabled

ON STABLE

= printing occurs each time the stability criteria are met.

INTERVAL

= printing occurs at the defined time interval.

ACCEPT

= in Checkweigh mode, printing occurs each time the display is within
the accept range and the stability criteria are met.

CONTINUOUS

= printing occurs continuously.




When ON STABLE is selected, set the conditions for printing.

LOAD

= Prints when the displayed load is stable.

LOAD ZERO

= Prints when the displayed load or zero reading is stable.




When INTERVAL is selected, set the time interval using the numeric keypad.

Settings of

1 to 3600 seconds are available.




3.9.4 Print Content Sub-menu

Enter this sub-menu to define the content of the printed data.

Result
Set the status.

OFF

= the displayed reading is not printed.

ON

= the displayed reading is printed.

NUMERIC ONLY = only the numeric portion of the displayed reading is printed.


Gross
Set the status.

OFF

= the gross weight is not printed.

ON

= the gross weight is printed.


12.000 kg

Net
Set the status.

OFF

= the net weight is not printed.

ON

= the net weight is printed.


12.000 kg

(ON)


12.000

(NUMERIC ONLY)


10.000 kg NET

INtEr

1

A.PrINt

OFF

rESULt

OFF

CONtNt

RESULT

GrOSS

OFF

CONtNt

GROSS

NEt

OFF

CONtNt

NET

ON.StAb

LOAD

Advertising