Assigning id numbers, Assigning id numbers -5 – KEYENCE DL-EP1 User Manual

Page 21

Advertising
background image

2-2 Installation and Connection to Sensor Amplifiers

2-5

2

Connec

tion and

Con

fig

ur

ati

on

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -

3

Mount the supplied end units (OP-26751: a set of two pieces) on the outer

ends of the amplifier and the EtherNet/IP Compatible Network Unit DL-

EP1. Then, fix the end units with the screws on the top of each end unit (2

points x 2 units). (Tightening torque : 0.6 Nm or less)

Mount the end units in the same way as the EtherNet/IP Compatible Network
Unit DL-EP1.

Several sensor amplifiers can be connected to the DL-EP1. ID numbers for data
identification are assigned to each sensor amplifier.
The method for assigning ID numbers is as follows:

• ID numbers are assigned in order, starting from the sensor amplifier that is the

main unit. (Optional numbers cannot be assigned.)

• 0 is assigned as the ID number of the DL-EP1.

• You cannot change the ID numbers assigned to the sensor amplifiers.
• In this manual, ID number 00 to ID number 08 are denoted as ID00 to

ID08, respectively.

Also for cyclic communication, output, current value, and external input are assigned
one by one per ID number.

For DIN rail mount type

Press the EtherNet/IP Compatible Network Unit DL-EP1, into

full engagement with the sensor amplifier. Energizing the DL-

EP1 when not inserted fully may damage the DE-EP1.

End unit

End unit

NOTICE

Assigning ID Numbers

Point

ID number

01

Main

unit

Expansion

unit

Expansion

unit

Expansion

unit

02

07

08

00