KEYENCE DL-EP1 User Manual

Page 77

Advertising
background image

3-4 Message Communication

3-49

3

Commu

nic
ati

ng

wi

th t
he SK-1000

S

eries

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -

• Commands

• Responses (when successful)

• Responses (when unsuccessful)

For details on the attribute ID, settings, general status, and additional status of each

parameter, refer to

"DL Object (Class ID:67H)" (Page 3-32) and

"Attributes"

(Page 3-34).

Item

Description

Data Example

Service Code

Designates the "operation command (4BH)" (fixed

value).

4BH

Class ID

Designates DL Object (67H)(fixed value).

67H

Instance ID

Designates the ID number. The ID number (00H) of the

DL-EP1 cannot be designated.

08H

Attribute ID

Designates the attribute ID to be designated from

"Attribute".

"(3) Issuing operation commands to a

sensor amplifier" "Attribute IDs supported by the

instance service 4BH (operation command)" (Page 3-

48)

0301H(769)

Service Data

There is no service response data.

-

Item

Description

Data Example

General status

A status (00H) is returned that indicates normal

completion of message communication.

00H

Service response data

There is no service response data.

-

Item

Description

Data Example

General status

A general status for the service is returned

08H

Additional status

An additional status is returned.

-

Service response data

There is no service response data.

-