4 message communication, Commu nic ati ng wi th t he sk-1000 s eries – KEYENCE DL-EP1 User Manual

Page 66

Advertising
background image

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -

3-4 Message Communication

3-38

3

Commu

nic
ati

ng

wi

th t
he SK-1000

S

eries

Group1

032BH

(811)

Bank status

Indicates the currently active bank No.

Use this attribute to check the bank No. for

which the sensor amplifier is actually

operating.

Parameter range: 0 to 3

0: Bank 0

1: Bank 1

2: Bank 2

3: Bank 3

R

DINT

032CH

(812)

Timing status

Indicates the currently active timing status.

Use this attribute to check the timing status

under which the sensor amplifier is actually

operating.

Parameter range: 0 to 1

0: During Sampling

1: Not during sampling

R

DINT

033DH

(813)

Temperature

*2

Indicates the current temperature.

Parameter range: -999.9 to +999.9

R

DINT

033EH

(814)

Humidity

*3

Indicates the current humidity.

Parameter range: 0.0 to 100.0

R

DINT

032FH

(815) to

0332H

(818)

(Reserved for system)

0333H

(819)

Abnormal

setting

*4

Indicates the abnormal setting state.

Parameter range: 0 to 1

0:Normal setting

1:Abnormal setting

R

DINT

0334H

(820)

External input

status

Indicates the external input status. When the

external input cable of the sensor amplifier or

the external input of the cyclic communication

is on, the corresponding bit turns on.

This operation is enabled even when "Not

used" is selected for the function setting of

external inputs 1 through 4.

Bit0:External input 1

Bit1:External input 2

Bit2:External input 3

Bit3:External input 4

R

DWORD

0335H

(821)

EEPROM write

result

*5

Indicates the result of writing to EEPROM.

Parameter range: 0 to 2

0:Writing

1:Normal termination

2:Abnormal termination

R

DINT

0336H

(822)

Zero shift/Zero

shift reset

result

*6

Indicates the result of zero shift or zero shift

reset.

Parameter range: 0 to 2

0:Executing

1:Normal termination

2:Abnormal termination

R

DINT

0337H

(823)

Reset request

result

Indicates the result of reset.

Parameter range: 0 to 2

0:Executing

1:Normal termination

2:Abnormal termination

R

DINT

Class

Attribute

ID

Name

Description

Attribute

Data

Type

Advertising