4 message communication, Commu nic ati ng wi th t he sk-1000 s eries – KEYENCE DL-EP1 User Manual

Page 70

Advertising
background image

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -

3-4 Message Communication

3-42

3

Commu

nic
ati

ng

wi

th t
he SK-1000

S

eries

Group4

0389H

(905)

(Reserved for system)

038AH

(906)

Timing input

setting

Set up timing input.

Parameter range: 0 to 1 (initial value: 0)

0:Level

1:Edge

R/W

DINT

038BH

(907) to

038CH

(908)

(Reserved for system)

038DH

(909)

Hysteresis

Set up hysteresis.

Parameter range: 0.000 to 99.999

(initial value: 0.100)

R/W

DINT

038EH

(910)

Analog output

scaling

*9

Set the analog output scaling.

(For main unit only.)

Parameter range: 0 to 1 (initial value: 0)

0: Initial state

1: Free range

R/W

DINT

038FH

(911)

Analog output

upper limit

*9

Set the analog output upper limit.

(For main unit only.)

Parameter range: -99.999 to 99.999

(initial value: +10.000)

R/W

DINT

0390H

(912)

Analog output

lower limit

*9

Set the analog output lower limit.

(For main unit only.)

Parameter range: -99.999 to 99.999

(initial value: -10.000)

R/W

DINT

0391H

(913)

External input

*10

Set up whether to change the function

assigned to external input 1/2/3/4 from the

initial state.

Parameter range: 0 to 1 (initial value: 0)

0:Initial state

1:User setting

R/W

DINT

0392H

(914)

External input 1

*10

Set up function to be assigned to external

input 1.

Parameter range: 0 to 3 (initial value: 0)

0:Zero shift input

1:Bank A input

2:Bank B input

3:Not used

R/W

DINT

0393H

(915)

External input 2

*10

Set up function to be assigned to external

input 2.

Parameter range: 0 to 3 (initial value: 0)

0:Reset input

1:Bank A input

2:Bank B input

3:Not used

R/W

DINT

0394H

(916)

External input 3

*10

Set up function to be assigned to external

input 3.

Parameter range: 0 to 3 (initial value: 0)

0:Timing input

1:Bank A input

2:Bank B input

3:Not used

R/W

DINT

0395H

(917)

External input 4

*10

Set up function to be assigned to external

input 4.

Parameter range: 0 to 2 (initial value: 0)

0:Bank A input

1:Bank B input

2:Not used

R/W

DINT

Class

Attribute

ID

Name

Description

Attribute

Data

Type

Advertising