KEYENCE DL-EP1 User Manual

Page 40

Advertising
background image

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -

3-3 Cyclic communication

3-12

3

Commu

nic
ati

ng

wi

th t
he SK-1000

S

eries

Current Value 0/Current Value 1

Output n (n: 1 to 5)

The ON/OFF status of output n (n: 1 to 5) of the sensor amplifier with the target

ID number is output.

Output 1: HI output

Output 2: LO output

Output 3: GO output

Output 4: Alarm output

Output 5: (Unassigned)

ON: Output n is output.

OFF: Output n is not output.

External Input

Response

n (n: 1 to 5)

An external input response is output when the corresponding external input

request n (n: 1 to 5) is made via communication.

The ID number of an unexisting external input is also output.

ON: The external input request was made (ON).

OFF: The external input request was not made (OFF).

For details, refer to

"Entering an external input to a sensor amplifier"

(Page 3-19).

Error ID Number

If "Error Status" in ON, the ID number of the DL-EP1 where the error occurred and

the ID numbers of sensor amplifiers connected to the DL-EP1 are stored (the ID

number of the DL-EP1 is 0). If no error has occurred, 0 is stored. If an error occurs

in multiple IDs, the ID number of the DL-EP1 or sensor amplifier where the highest

priority error occurred is stored.

Error priority:

(1) DL-EP1 error

(2) Sensor amplifier errors (the error with the smallest error code has the

highest priority)

*

* If the same error code occurs in multiple sensor amplifiers, the error

with the smallest ID number has the highest priority.

Error Code

If "Error Status" is ON, the error code is stored. If no error has occurred, 0 is

stored. If an error occurs in multiple IDs, the error code of the DL-EP1 or sensor

amplifier where the highest priority error occurred is stored.

Error priority:

(1) DL-EP1 error

(2) Sensor amplifier errors (the error with the smallest error code has the

highest priority)

*

* If the same error code occurs in multiple sensor amplifiers, the error

with the smallest ID number has the highest priority.

"Error code list" (Page 3-13)

Warning ID

Number

(Unassigned)

Warning Code

(Unassigned)

Current Value n

(n: 0 to 1)

The current value n (n: 0 to 1) of the sensor amplifier is stored. The current value

0 always exists without reference to sensor amplifier models. Whether the

current value 1 exists depends on sensor amplifier models. If the current value

1 does not exist, 0 is stored. The contents displayed in the current value n (n: 0

to 1) depend on the use conditions.

"Current Value 0/Current Value 1" (Page 3-12)

(* The current value 1 does not exist in the SK-1000 Series.)

Item

Description

Name

Model

Conditions

Function

Current Value 0

Main unit/

expansion unit

-

Judgment value (P.V.)

Current Value 1

Main unit/

expansion unit

-

(Unassigned)

Advertising