3-4 Message Communication

3-43

3

Commu

nic
ati

ng

wi

th t
he SK-1000

S

eries

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -

Group4

0396H

(918)

Bank switching

method

Set up method for switching the Bank.

Parameter range: 0 to 1 (initial value: 0)

0:Button

1:External input

R/W

DINT

0397H

(919)

(Reserved for system)

0398H

(920)

Zero shift value

memory

function

Set up whether to save the zero-shift state.

Parameter range: 0 to 1 (initial value: 0)

0: OFF

1: ON

R/W

DINT

0399H

(921)

(Reserved for system)

039AH

(922)

Display digit

Set up display digit. (initial value: 0)

0:Initial state

1:0.001

2:0.01

3:0.1

4:1

R/W

DINT

039BH

(923) to

039FH

(927)

(Reserved for system)

Group5

03A0H

(928)

Group5

Entry count

Indicates the No. of Group 5 entries.

Parameter range: 4

R

DINT

03A1H

(929)

Distance

correction

method

Set the distance correction method.

Parameter range: 0 to 1 (initial value: 0)

0: Initial state

1: User setting

R/W

DINT

03A2H

(930)

Near-side

distance

correction

amount

Set the near-side distance correction amount.

Parameter range: 5 to 50

(initial value: 25)

R/W

DINT

03A3H

(931)

Far-side

distance

correction

amount

Set the far-side distance correction amount.

Parameter range: 60 to 120

(initial value: 100)

R/W

DINT

03A4H

(932)

Area scaling

Set the area scaling.

Parameter range: 0.10 to 1.50

(initial value: 1.00)

R/W

DINT

03A5H

(933) to

03BFH

(959)

(Reserved for system)

Group6

03C0H

(960)

Group6

Entry count

Indicates the No. of Group 6 entries.

Parameter range: 11

R

DINT

03C1H

(961)

Product code

Indicates the product code.

Main unit

: 4024

Expansion unit : 4025

R

DINT

03C2H

(962)

Revision

Indicates the revision.

The higher-order bytes in the lower-order word

indicate the major revision and the lower-order

bytes indicate the minor revision.

Parameter range: 0101H

R

DINT

03C3H

(963)

Connected

sensor head

Indicates model of sensor head connected to

the amplifier.

0:Not connected

1:The head is connected

R

DINT

Class

Attribute

ID

Name

Description

Attribute

Data

Type

Advertising