3-4 Message Communication

3-45

3

Commu

nic
ati

ng

wi

th t
he SK-1000

S

eries

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -

A value to be read or written is specified as on/off status of the bits
representing the value converted into binary.

When the read data is "6":
The decimal number "6" is represented in binary as "0110".

As a result, the sensor amplifier of the read data is set to "NPN output" and
"analog output of 1 to 5 V".

*8

Operates as "off" only when input off (0) is written and the external input is off
for both cable and cyclic communication.

*9

When a value is written to an expansion unit, a writing error occurs.

*10 To reflect the settings written for the function selection of external inputs 1 to 4

(0392H (914) to 0395H (917)) to the sensor amplifier, you need to set the
external input setting (0391H (913)) to 1 (User setting) or to operate the sensor
amplifier's button to set the external input to "User setting".

Bit

Setting

0

0: NPN output

1: PNP output

3, 2, 1

000: Analog output OFF

001: 0 to 5 V

010: -5 to +5 V

011: 1 to 5 V

100: 4 to 20 mA

(Fixed to 000 for expansion unit)

Reference

011 0

Bits 3, 2, 1: 1 to 5 V

Bit 0: NPN output