4 message communication, Commu nic ati ng wi th t he sk-1000 s eries – KEYENCE DL-EP1 User Manual

Page 67

Advertising
background image

3-4 Message Communication

3-39

3

Commu

nic
ati

ng

wi

th t
he SK-1000

S

eries

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -

Group1

0338H

(824)

Current system

parameters

*7

Indicates the current status of the system

parameters. Use this attribute to check the

system parameters with which the sensor

amplifier is actually operating.

The corresponding bit turns on according to

the current status.

bit 0:

0:NPN

1:PNP

bits 1, 2 and 3 (For main unit only. Fixed to 000

for expansion unit)

000: Analog output OFF

001: 0 to 5 V

010: -5 to +5 V

011: 1 to 5 V

100: 4 to 20 mA

R

DINT

0339H

(825) to

033FH

(831)

(Reserved for system)

Group2

0340H

(832)

Group2 Entry

count

Indicates the No. of Group 2 entries.

Parameter range: 17

R

DINT

0341H

(833)

HI setting value

(BANK 0)

Set up setting value of HI side (BANK 0).

Parameter range: -99.999 to +99.999

(initial value: +1.000)

R/W

DINT

0342H

(834)

LO setting value

(BANK 0)

Set up setting value of LO side (BANK 0).

Parameter range: -99.999 to +99.999

(initial value: -1.000)

R/W

DINT

0343H

(835) to

0345H

(837)

(Reserved for system)

0346H

(838)

HI setting value

(BANK 1)

Set up setting value of HI side (BANK 1).

Parameter range: -99.999 to +99.999

(initial value: +1.000)

R/W

DINT

0347H

(839)

LO setting value

(BANK 1)

Set up setting value of LO side (BANK 1).

Parameter range: -99.999 to +99.999

(initial value: -1.000)

R/W

DINT

0348H

(840) to

034AH

(842)

(Reserved for system)

034BH

(843)

HI setting value

(BANK 2)

Set up setting value of HI side (BANK 2).

Parameter range: -99.999 to +99.999

(initial value: +1.000)

R/W

DINT

034CH

(844)

LO setting value

(BANK 2)

Set up setting value of LO side (BANK 2).

Parameter range: -99.999 to +99.999

(initial value: -1.000)

R/W

DINT

034DH

(845) to

034FH

(847)

(Reserved for system)

0350H

(848)

HI setting value

(BANK 3)

Set up setting value of HI side (BANK 3).

Parameter range: -99.999 to +99.999

(initial value: +1.000)

R/W

DINT

0351H

(849)

LO setting value

(BANK 3)

Set up setting value of LO side (BANK 3).

Parameter range: -99.999 to +99.999

(initial value: -1.000)

R/W

DINT

Class

Attribute

ID

Name

Description

Attribute

Data

Type