Chapter 7. Using the Diagnostics Pages

IO-Link Master 4-EIP User Guide: 2000582 Rev. A

Modbus/TCP Diagnostics

7.3. Modbus/TCP Diagnostics

The Modbus/TCP Diagnostics page may be useful when trying to troubleshoot Modbus/TCP communications
or port issues related to Modbus/TCP configuration.

The following table provides information about the Modbus/TCP Diagnostics page.

Modbus/TCP Diagnostics

Active Connections

Displays the current number of active Modbus/TCP connections.

Messages Received from
Masters

Displays the number of Modbus messages received from Modbus/TCP
Masters.

Responses Sent to Masters

Displays the number of Modbus responses sent to Modbus/TCP Masters.

Broadcasts Received

Displays the number of broadcast Modbus/TCP messages received.

Invalid Message Length
Errors

Displays the number of Modbus messages received with incorrect length
fields.

Invalid Message Data Errors

Displays the number of invalid message data errors. These errors occur
when the IO-Link Master receives a message that cannot be performed due
to invalid data.