Connect the digital input s and relay outputs – Comtrol ES8510-XTE User Manual

Page 10

Advertising
background image

10 - Connect the Digital Input s and Relay Outputs

RocketLinx ES8510-XTE User Guide: 2000574 Rev. C

Hardware Installation

b.

Tighten the wire-clamp screws to prevent the wires from coming loose.

• PWR1 and PWR2 support power redundancy and reverse polarity protection.

• Accepts a positive or negative power source but PW1 and PW2 must apply to the same mode.

• If both power inputs are connected, the ES8510-XTE is powered from the highest connected

voltage.

• The ES8510-XTE can emit an alarm if PW1 or PW2 are no longer receiving power. See the

Warning

discussion on

Page 109

to configure an alarm.

2.

Connect a ground wire between the chassis and earth ground using
12-24AWG wire to ensure that the ES8510-XTE is not damaged by
noise or electrical shock.

a.

Loosen the chassis ground screw on the bottom of the
ES8510-XTE.

b.

Insert the ground wire.

c.

Tighten the ground screw after the earth ground wire is
connected.

Connect the Digital Input s and Relay Outputs

The ES8510-XTE provides two digital inputs and two digital outputs (dry relay output) on terminal block
connectors on the bottom of the unit. The fault conditions can be configured in the web user interface or
Command Line Interface (CLI) and include:

DI State

Power failure

Ethernet port link break

Dry output

Ping failure

Super Ring failure

You can configure events using one of the ES8510-XTE user interfaces (

Fault Relay

on Page 109) or the

Command Line Interface (

Global Configuration Mode

on Page 133).

The Digital Input pin can be pulled high
or low so that the connected equipment
can actively drive these pins. The web
user interface allows you to read and set
the value to the connected device. The
power input voltage of logic low is 0 to
10VDC and logic high is 11 to 30VDC.
Do not apply a higher voltage than the
specification; it may cause internal
circuit damage or a cause an incorrect
DI action.

Digital Input