Mount the es8510-xte – Comtrol ES8510-XTE User Manual

Page 11

Advertising
background image

RocketLinx ES8510-XTE User Guide: 2000574 Rev. C

Mount the ES8510-XTE - 11

Hardware Installation

Digital output relay contacts are
energized (open) for normal operation
and close for fault conditions. The
digital output relay contacts support up
to 1A at 30VDC. Do not apply voltage
and current higher than the
specifications.

1.

Insert the positive and negative
wires (12-24 AWG) into V+ and V-.

2.

Tighten the wire-clamp screws to
prevent the wires from coming
loose.

Mount the ES8510-XTE

You can use the following procedure to mount the ES8510-XTE on a DIN rail or on the wall.

The DIN rail clip is already attached to the ES8510-XTE. If the DIN rail clip is not screwed onto the
ES8510-XTE, follow the instructions and the figure below to attach DIN rail clip to the ES8510-XTE.

Digital Output

1.

If necessary, use the screws to attach DIN rail clip to the rear
panel of the ES8510-XTE. (To remove DIN rail clip, reverse Step
1.)

2.

Insert the upper end of DIN rail clip into the back of DIN rail
track from its upper side.

3.

Lightly push the bottom of DIN rail clip into the track.

4.

Verify that the DIN rail clip is tightly attached on the track.

5.

To remove the ES8510-XTE from the track, reverse the steps
above.

DIN Rail Mounting

Follow the steps below to install the ES8510-XTE with the wall mounting plate:

1.

To remove the DIN rail clip from the ES8510-XTE, loosen the screws from the DIN rail
clip.

2.

Place the wall mounting plate on the rear panel of the ES8510-XTE.

3.

Use the screws to attach the wall mounting plate to the ES8510-XTE.

4.

Use the hook holes at the corners of the wall mounting plate to hang the ES8510-XTE
onto the wall.

5.

To remove the wall mounting plate, reverse the steps above.

Wall Mount Installation