Testing sensors

You can test sensors one at a time to make sure they are sending strong signals
to the panel. You should test the security system at least once a week. To test
sensors, do the following:

1. Scroll to

System tests

and press Enter.

2. The display shows

Enter code

. Enter your master code with the numbered

keys and press Enter to accept the master code.

3. The display shows

Sensor test

. Press Enter.

4. The display shows, for example,

Trip Sn 1 Front Door

and automatically

displays the list of sensors to be tested. The panel sounds six beeps once a
minute while in sensor test mode and the piezo beeps for each packet
received. See Table 12 below. When you trip a sensor the display shows, for
example,

Sn 1 Packets = 8 Front Door

. You may trip the sensors in any order.

As each sensor is heard from, it is removed from the list of sensors to be
tested. After all sensors have been successfully tested, the display shows

Sn

test complete, press Status

.

To terminate the sensor test, do the following:

1. Press Status. The display shows Sensor test OK.

2. After a few seconds the display shows

Sensor test

. Press Status repeatedly to

exit.

If any of the sensors did not test successfully and you want to terminate the test,
press Status. The panel display will show

Sensor test fail or aborted

. The display

then shows

Sensor test

. Press Status once to exit the system test. If a sensor

test fails, call your security dealer.

Table 12: How to trip devices for sensor test

Device

To trip device

Door/window sensor

Open the secured door or window.

Freeze sensor

Apply ice to the sensor. Do not allow the sensor to get wet.

Water sensor

Press a wet rag or wet finger over both of the round, gold-plated
terminals on the underside of the sensor.

Carbon monoxide
sensor

Unplug the CO alarm. Plug it back in and press the test/reset button
until the unit beeps 8 times.

Glass guard sensor

Tap the glass 3 or 4 inches (6 to 8 cm) from the sensor.

Motion sensor

Avoid the motion sensor’s view for five minutes, then enter its view.

Shock sensor

Tap the glass twice, away from the sensor. Wait at least 30 seconds
before testing again.