Field Title

Description

Free Space (MB)

If the drive has not been filled yet, it will show available free space in MB. “0”
Free Space means the drive is in Overwrite mode (provided overwrite was
specified for system recording)

Status

Normal or Standby.

Normal means data is being read/written to the drive.

Standby means the drive is spun down to save energy since no data is being
read/written to the drive.

Type

All hard drives are Local within the box. A future release may support
attached eSata drive extension to the box.

HDD Group

Shows which hard drive group the drive is associated with. Up to eight (8)
Hard Drive Groups may be defined. Default setting is HDD Group 1

Attribute

The available settings are: Read-Write, Redundant, Read. Normal operation
for a drive is Read-Write.

Use the Redundant setting if the drive is the destination for duplicate camera
recording.

Read designates the drive as read-only. This setting is only used if there is
data on the drive that you do not want to be overwritten or you are setting up a
record-till-full and stop operation.

Figure 32: HDD Settings

TIP: The HDD Group and Attribute fields are not normally viewable in the
Window unless the scrollbar is moved to the right to expose the fields.
Additionally, to view the settings in these fields better, the User will want to
expand the field by placing their cursor at the field title left border and dragging to
review more data in the field. This is similar to what is done inside of typical
spreadsheets.

Please note: If you have changed the default hard drive configuration and wish to
restore the normal hard drive configuration, press the Default button and this will
return your unit to the factory defaults for all settings including the HDD Group
configuration. None of your existing video data will be lost.