Pecifications, Escription – Conair B32 User Manual

Page 12

Advertising
background image

S

PECIFICATIONS

Basic 32 Loader Control

UGC007/0702

2-4

D

ESCRIPTION

MODEL

B32

Performance characteristics

Maximum number of vacuum receivers

32

Maximum number of vacuum pumps

8 (plus back-up)

Programmable logic controller

Allen Bradley Micrologix 1500

Touchscreen operator interface

Allen Bradley PV300 Micro

Communications with master control

DH485

Screen size, inches {mm}

2.87 X 1.67 {73 X 42}

User interface method

Keypad

Output voltage to receivers/valves

24 VDC

Sensor voltage to receivers

24 VDC

Output voltage to pumps

24 VDC

Dimensions inches {mm}

Master control cabinet
A - Height

31.4 {998}

B - Width

23.8 {606}

C - Depth

12.5 {318}

Weight lb {kg}

Installed

70 {32}

Shipping

85 {39}

Voltages Total amps

115V/1 phase/60Hz (master control)

10

CALCULATING CABLE LENGTH:

Total the distances from the Input/output Station(s) location to each vacu-
um receiver on the system. Be sure to account for reasonable slack at
each loading station for connections, cable routing, etc.

APPLICATION NOTES:

Conair vacuum receivers come equipped with a quick-disconnect connec-
tor set that includes 10 feet of cable. Junction boxes must be provided to
connect the system cable and each vacuum receiver’s connector set.

SPECIFICATION NOTES:

B32 loader control cable: 18 gauge shielded, 8-conductor may be used
for standard vacuum receivers with up to one optional output and input,
otherwise 10-conductor cable is required.

Specifications can change without notice. Check with your Conair
representative for the most current information.

A

B

C

5.5 inch screen

(optional)

3 inch screen

standard

Advertising