Basic 32 Loader Control UGC007/0702

Fault Messages and Error Codes D-7

0083

MAX I/O CABLES
EXCEEDED

The maximum number of expansion
I/O cables allowed was exceeded.

Non-User

Reconfigure the expansion I/O system so
that it has an allowable number of cables.

Cycle power.

0084

MAX I/O POWER
SUPPLIES EXCEEDED

The maximum number of expansion
I/O power supplies allowed was
exceeded.

Non-User

Reconfigure the expansion I/O system so
that it has the correct number of power
supplies.

0085

MAX I/O MODULES
EXCEEDED

The maximum number of expansion
I/O modules allowed was exceeded.

Non-User

Reconfigure the expansion I/O system so
that it has an allowable number of
modules.

Cycle power.

xx86

(1)

EXPANSION I/O
MODULE BAUD RATE
ERROR

An expansion I/O module could not
communicate at the baud rate
specified in the user program I/O
configuration.

Non-User

Change the baud rate in the user program
I/O configuration, and

Re-compile, reload the program and enter
the Run mode, or

Replace the module.

Cycle power.

xx87

(1)

I/O CONFIGURATION
MISMATCH

The expansion I/O configuration
in the user program did not match
the actual configuration, or

The expansion I/O configuration
in the user program specified a
module, but one was not found,
or

The expansion I/O module
configuration data size for a
module was greater than what
the module is capable of holding.

Non-User

Either correct the user program I/O
configuration to match the actual
configuration, or

With power off, correct the actual I/O
configuration to match the user program
configuration.

xx88

(1)

EXPANSION I/O
MODULE
CONFIGURATION
ERROR

The number of input or output image
words configured in the user
program exceeds the image size in
the expansion I/O module.

Non-User

Correct the user program I/O configuration
to reduce the number of input or output
words, and

Re-compile, reload the program and enter
the Run mode.

xx89

(1)(2)

EXPANSION I/O
MODULE ERROR

An expansion I/O module generated
an error.

Non-User

Refer to the I/O status file.

Consult the documentation for your
specific I/O module to determine possible
causes of a module error.

xx8A

(1)(2)

EXPANSION I/O
CABLE
CONFIGURATION
MISMATCH ERROR

Either an expansion I/O cable is
configured in the user program,
but no cable is present, or

an expansion I/O cable is
configured in the user program
and a cable is physically present,
but the types do not match.

Non-User

Correct the user program to eliminate a
cable that is not present

Re-compile, reload the program and enter
the Run mode, or

Add the missing cable.

Cycle power.