Rocessor and, Ower, Roblems – Conair B32 User Manual

Page 44: Possible cause solution, Perator, Nterface, Possible cause, Solution

Advertising
background image

P

ROCESSOR

AND

P

OWER

P

ROBLEMS

Fault

Possible cause

Solution

O

PERATOR

I

NTERFACE

P

ROBLEMS

Basic 32 Loader Control

UGC007/0702

6-8

T

ROUBLESHOOTING

Fault

Terminal does not
power up.

Possible cause

Improper connection to
power source

Incorrect input voltage
level.

DC power wires reversed
(DC terminals only).

Power terminal block not
fully seated (PV300 ter-
minals only).

Solution

r Verify wiring and connec-

tions to power source.

r Verify correct voltage is

present at power terminals.

r Make sure DC power posi-

tive and negative are con-
nected to the proper termi-
nals.

r Verify power terminal

block is snapped onto base
of PV300 Micro.

WARNING:

Electrical shock hazard

Diagnosing electrical and processor problems
require access to the electrical enclosure while
power is on. Only qualified electrical technicians,
who are trained in how to avoid voltage hazards,
should perform troubleshooting procedures that
require access to the B32 Input/Output enclo-
sure while power is on.

WARNING:

Electrical shock hazard

Diagnosing electrical and processor problems
require access to the electrical enclosure while
power is on. Only qualified electrical technicians,
who are trained in how to avoid voltage hazards,
should perform troubleshooting procedures that
require access to the B32 Input/Output enclo-
sure while power is on.

See

A

PPENDIX

C “T

ROUBLESHOOTING

Y

OUR

S

YSTEM

for a complete listing of

process and power faults, causes and solutions.