Etting, Oader, Arameters – Conair B32 User Manual

Page 22

Advertising
background image

Basic 32 Loader Control

UGC007/0702

3-10

I

NSTALLATION

S

ETTING

L

OADER

P

ARAMETERS

The loader must be correctly installed and wired before setting
parameters.

To set loader parameters from the main screen:

Use the Up/Down arrows to scroll to

Loader Settings.

Press the Enter arrow.

The Loader Settings screen displays. Use the
up/down arrows to scroll to Settings.

Press the Enter arrow.

The Settings screen displays. Use the left/right
arrows to scroll to move the cursor to the Loader
field. Use the up/down arrows to select loader.

Use the Scroll Down/Up buttons to set the
loader

parameters: loader number, virgin time in seconds,
dump time in seconds and pump number.

CAUTION: Incorrect configurations will
cause the B32 control to stop.

Before enabling loaders and loading functions,
make sure the loader, valve or option has been
installed in the system. Each loader and feature
must be wired to a correctly installed and enabled
input or output module. The B32 will fault and the
loading control will stop if the required I/O module
has not been installed for the feature you enabled.