When Operating Normally

The POWER and RUN LEDs are on. If a force condition is active, the FORCE
LED turns on and remains on until all forces are removed.

When an Error Exists

If an error exists within the controller, the controller LEDs operate as described in
the following tables.

If the LEDS
indicate:

The Following
Error Exists

Probable Cause

Recommended Action

All LEDS off No input power or

power supply error

No Line Power

Verify proper line voltage and
connections to the controller.

Power Supply
Overloaded

This problem can occur intermittently if
power supply is overloaded when output
loading and temperature varies.

Power and
FAULT LEDs
on solid

Hardware faulted

Processor
Hardware Error

Cycle power. Contact your local

Conair Service representative if
the error persists.

Loose Wiring

Verify connections to the controller.

Power LED
on and
FAULT LED
flashing

Application fault

Hardware/
Software Major
Fault Detected

4. Monitor Status File Word S:6 for

major error code. See page C-4 for
more information.

5. Remove hardware/software

condition causing fault.

6. Clear Major Error Halted flag, bit

S2:1/13.

7. Attempt a controller Run mode entry.

If unsuccessful, repeat recommended
action steps above or contact your

Coniar Service representative.