Serial Control Register
SCON, 098H

D7

D6

D5

D4

D3

D2

D1

D0

SM0

SM1

SM2

REN

TB8

RB8

TI

RI

RW-0

RW-0

RW-0

RW-0

RW-0

RW-0

RW-0

RW-0

R = Unrestricted Read Access, W = Unrestricted Write Access, T = Timed-access Write Only, n = Value after Reset, * = Special: see description

SCON.7, SCON.6:

SM0, SM1

“Mode Select”:

Used to select the operational mode of the serial I/O port as follows:

SM0

SM1

MODE

FUNCTION

LENGTH (BITS)

CLOCK PERIOD

0

0

0

SYNC

8

12 t

CLK

0

1

1

ASYNC

10

Timer 1 Overflow

1

0

2

ASYNC

11

64 t

CLK

or 32 t

CLK

1

1

3

ASYNC

11

Timer 1 Overflow


SCON.5

SM2

Multiple MCU Comm

Used to enable the multiple microcontroller communications feature for modes 2
and 3. When SM2 = 1, RI IS activated only when serial words are received which
cause RB8 to be set to 1.


SCON.4

REN

Receive Enable

When set to 1, the receive shift register is enabled. Disabled when cleared to 0.


SCON.3

TB8

Transmitted Bit 8

Can be set or cleared to define the state of the 9th data bit in modes 2 and 3 of a
serial data word.


SCON.2

RB8

Received Bit 8

Indicates the state of the 9th data bit received while in modes 2 or 3. If mode 1 is
selected with SM2 = 0, RB8 is the state of the stop bit which was received. RB8 is
not used in mode 0.


SCON.1

TI

Transmit Interrupt

Status bit used to signal that a data word has been completely shifted out. In mode
0, it is set at the end of the 8th data bit. Set when the stop bit is transmitted in all
other modes.


SCON.0

RI

Receive Interrupt

Status bit used to signal that a serial data word has been received and loaded into
the receive buffer register. In mode 0, it is set at the end of the 8th bit time. It is set
at the midbit time of the incoming stop bit in all other modes of a valid received
word according to the state of SM2.