Rpc control register—rpctl (0d8h) – Maxim Integrated Secure Microcontroller User Manual

Page 108

Advertising
background image

Secure Microcontroller User’s Guide

108 of 187

RPC Control Register—RPCTL (0D8H)

RNR

EXBS

AE

IBI

DMA

RPCON

RG0


RPCTL.3:

IBI

When using the RPC mode, an interrupt may be required for the Input Buffer Flag.
This interrupt is enabled by setting the input buffer interrupt (IBI) bit. At this time,
the timer 1 interrupt is disabled, and this RPC mode interrupt is used in its place
(vector location 1BH). This bit can be set only when the RPCON bit is set.

Initialization:

Cleared on all resets, and when the RPCON bit is cleared.

Read Access:

Can be read at any time.

Write Access:

Can be written when RPC mode is enabled (RPCON = 1).


RPCTL.2:

DMA

This bit is set to enable DMA transfers when RPC mode is invoked. It can only be
set when RPCON = 1.

Initialization:

Cleared on all resets, and when the RPC is cleared.

Read Access:

Can be read at any time.

Write Access:

Can be written when RPC mode is enabled (RPCON = 1).


RPCTL.1:

RPCON

Enable the 8042 I/O protocol. When set, Port 0 becomes the data bus, and Port 2
becomes the control signals as shown in

Figure 12-6

.

Initialization:

Cleared on all resets.

Read Access:

Can be read at any time.

Write Access:

Can be written at any time.