Imu advanced settings, Setting, Default value – Moog Crossbow GNAV540 User Manual

Page 26: Comments, Vertical gyroscope (vg) function, Anced settings, Rtical gyroscope (vg) function, Vg fun, Table 7 imu function advanced settings

Advertising
background image

 

 

 

 

GNAV540 User Manual

7430‐0808‐01 Rev. B

Page 26 

 

 

NOTE: The Delta‐Theta, Delta‐V packet is only recommended for use in continuous output mode at 5Hz or greater.  

Polled requests for this packet will produce values accumulated since the last poll request; they are subject to 
overflow (data type wrap around). 

 

IMU Advanced Settings 

The IMU advanced settings are described in Table 7 below.   All of the advanced settings are accessible thru NAV‐
VIEW 2.2 under the Configuration Menu→Unit Configuration settings. For information about using NAV‐VIEW 2.2, 
refer to Chapter 7. Configuring GNAV540 with NAV­VIEW 2.2.

Table 7  IMU Function Advanced Settings 

Setting   

Default Value 

Comments 

Baud Rate 

38,400  

9600, 19200, 57600 also available 

Packet Type 

S1 

S2 also available 

Packet Rate 

100Hz 

This sets the rate at which the selected Packet Type packets are output.  If polled 
mode is desired, then select Quiet.  If Quiet is selected, the unit will only send 

measurement packets in response to GP commands.  

Orientation 

See Figure 4 on 
page 24

To configure the axis orientation, select the desired measurement for each axis: 
NAV‐VIEW 2.2 will show the corresponding image of the unit, so it easy to 

visualize the mode of operation.  Refer to Orientation Field on page 86 for the 
twenty four possible orientation settings.  The default setting points the 

connector AFT. 

Vertical Gyroscope (VG) Function 

The Vertical Gyroscope (VG) Function provides dynamic roll and pitch measurements in addition to the IMU 
Function data. The dynamic roll and pitch measurements are stabilized by using the accelerometers as a long‐term 

gravity reference.  The VG Function can also output a free integrating yaw angle measurement that is not stabilized 

by a magnetometer or compass heading.   
At a fixed 100Hz rate, the VG Function continuously maintains both the digital IMU data as well as the dynamic roll 

and pitch data.  As shown in the software block diagram (Figure 2 on page 23), after the Sensor Calibration block, the 
IMU data is passed into an Integration to Orientation block. (If using external GPS, refer to Figure 4 on page 24.) The 

Integration to Orientation block integrates body frame sensed angular rate to orientation at a fixed 100 times per 

d singul

ealing with the cosine rot

thm to p

e propagation. 

second.  For improved accuracy and to avoi

arities when d

ation matrix, a 

quaternion formulation is used in the algori

rovide attitud

Also shown in the software block diagram (Figure 2, page 23) the Integration to Orientation block receives drift 

corrections from the Extended Kalman Filter or Drift Correction Module.  In general, rate sensors and accelerometers 
suffer from bias drift, misalignment errors, acceleration errors (g‐sensitivity), nonlinearity (square terms), and scale 

factor errors.   
The largest error in the orientation propagation is associated with the rate sensor bias terms.  The Extended Kalman 

Filter (EKF) module provides an on‐the‐fly calibration for drift errors, including the rate sensor bias, by providing 

corrections to the Integration to Orientation block and a characterization of the gyroscope bias state.  In the VG 
Function, the internally computed gravity reference vector provides a reference measurement for the EKF when the 

unit is in quasi‐static motion to correct roll and pitch angle drift and to estimate the X and Y gyroscope rate bias.   
Because the gravity vector has no horizontal component, the EKF has no ability to estimate either the yaw angle 

error or the Z gyroscope rate bias.    