Page 28 
 

GNAV540 User Manual

7430‐0808‐01 Rev. B

 

 

Setting 

Default Value 

Comments 

Freely 
Integrate 

OFF 

The Freely Integrate setting allows configuring the unit into a free gyroscope.  In 
free gyroscope mode, the roll, pitch and yaw are computed exclusively from 

angular rate with no Kalman filter based corrections of roll, pitch, or yaw.  When 
turned on, there is no coupling of acceleration based signals into the roll and 

y with 

pitch.  As a result, the roll, pitch, and yaw outputs will drift roughly linearl
time due to sensor bias.     
For best performance, the Freely Integrate mode should be used after the 
algorithm has initialized.  This allows the Kalman Filter to estimate the roll and 

pitch

 rate sensor bias prior to entering the free gyroscope mode.   Exiting the fre

scope mode (OFF), causes one of the following behaviors to occur: 

gyro

If the unit has been in freely integrate mode for less than sixty seconds, the 
algorithm will resume operation at normal gain settings. 

If the unit has been in freely integrate mode for greater than sixty seconds, 

the algorithm will force a reset and reinitialize with high gains automatically.  

 

Restart On 

Over Range 

OFF 

This setting forces an algorithm reset when a sensor over range occurs, i.e., a 

rotational rate on any of the three axes exceeds the maximum range.   The default 
setting is OFF.  Algorithm reset returns the unit to a high gain state, where the 

unit rapidly estimates the gyroscope bias and uses the accelerometer feedback 

 

heavily.   This setting is recommended when the source of over‐range is likely to

be sustained and potentially much greater than the rate sensor operating limit.   
Large and sustained angular rate over‐ranges result in unrecoverable errors in 

roll and pitch outputs.  An unrecoverable error indicates the EKF cannot stabilize 

the resulting roll and pitch reading.    If the over‐ranges are expected to be of 

m operating 

 turned off.     

short duration (<1 sec) and a modest percentage over the maximu

range, it is recommended that the restart on over range setting be
Han

g an inertial rate se

dlin

nsor over‐range is controlled with the 

rtOnOverRange

resta

 switch.   

• If  restartOnOverRange is off, the system will flag the overRange status flag 

and continue to operate through it.   

• If restartOnOverRange is on, the system will flag a masterFail error during an 

over‐range condition and continue to operate with this flag until a quasi‐

static condition is met to allow for an algorithm restart.   

The quasi‐static condition required is that the absolute value of each low‐pass 

ill 

filtered rate sensor falls below 3 deg/sec to begin initialization.  The system w
then attempt a normal algorithm start.  

Dynamic 
Motion 

ON 

The default setting is ON.   Turning off the dynamic motion setting results in a 
higher gain state that uses the accelerometer feedback heavily.   During periods of 

d off 

time when there is known low dynamic acceleration, this switch can be turne
to allow the attitude estimate to quickly stabilize.   

Turn Switch 
threshold 

10.0 deg/sec 

With respect to centripetal or false gravity forces from turning dynamics (or 
coordinated turn), the unit monitors the yaw‐rate.  If the yaw rate exceeds a given 

turn switch threshold, the feedback gains from the accelerometer signals for 

attitude correction are reduced because they are likely corrupted. 