Setting 

Defa

ue 

ult Val

Comments 

Orientation 

See Figure 4 o
page 24. 

To configure the axis orientation, select the desired measurement for each axis: 
NAV‐VIEW 2.2 then shows the corresponding image of the unit, making it easy to 

visualize the mode of operation.  Refer to Orientation Field on page 86 for the 

ints the 

twenty four possible orientation settings.  The default setting po

connector AFT. 

Freely 
Integrate 

OFF 

The Freely Integrate setting allows a user to turn the unit into a free gyroscope.  In 
free gyroscope mode, the roll, pitch and yaw are computed exclusively from 

angular rate with no Kalman filter based corrections of roll, pitch, or yaw.  When 

turned on, there is no coupling of acceleration based signals into the roll and pitch 

tch, and 

or magnetometer based signals to the yaw.  Due to sensor bias., the roll, pi

yaw outputs will drift roughly linearly with time. 
For best performance, the Freely Integrate mode should be used after the 

algorithm has initialized.  This allows the Kalman Filter to estimate the roll and 
pitch rat

the free 

e sensor bias prior to entering the free gyroscope mode.    Upon exiting 

gyroscope mode (OFF), one of two behaviors will occur: 

nds, 

If the unit has been in freely integrate mode for less than sixty seco

the algorithm will resume operation at normal gain settings 

• If the unit has been in freely integrate mode for greater than sixty 

seconds, the algorithm will force a reset and reinitialize with high gains 

automatically.  

 

Use Mags 

ON 

The 

 

yaw

Use Mags setting enables turning on and off the magnetometer feedback for

/heading stabilization.   

• The default setting is ON.  When Use Mags is turned ON, the GNAV540  unit 

uses the magnetic field sensor readings to stabilize the drift in yaw, and it 
slaves the yaw to the compass reading provided from the magnetic field 

sensor readings.    

• When Use Mags is turned OFF, the heading (yaw) angle measurement of the 

unit will drift and freely integrate.  In effect, this setting converts the 

 

functionality to VG.  However, unlike a unit in the VG Function, this can be

done on a selectable basis and changed in real time during a mission.    

This setting enables turning off the magnetometer stabilization when severe 

magnetic distortion may be occurring.  This setting is desirable when the system 
temporarily moves in close proximity to a large ferrous object.    When the Use 

Mags switch is turned from OFF to ON, the unit will reinitialize the yaw/heading 

ngle with the compass reading provided from the magnetic field sensor 

eadings. 

a
r
 

Advertising