This command performs a core CPU reset, functionally equivalent to a power cycle. All default power‐up field 

settings will apply.  The unit will respond with software reset response before the system goes down.   

Software Reset Response 

Table 23  Software Reset Response 

Software Reset (‘SR’ = 0x5352) 

Preamble  Packet Type 

Length 

Termination 

0x5555 

0x5352 

0x00 

<CRC (U2)> 

The unit will send this packet in response to a software reset command.   

Calibrate Command 

Table 24  Calibrate Command 

Calibrate (‘WC’ = 0x5743) 

Preamble  Packet Type 

Length 

Payload 

Termination 

0x5555 

0x5743 

0x02 

<WC payload> 

<CRC (U2)> 

This command allows the user to perform various calibration tasks with the GNAV540 unit.  See the calibration 

command table below for details.  The unit will respond immediately with a calibrate response containing the 
calibrationRequest

received or an error response if the command cannot be performed.   

Table 25  WC Payload 

WC Payload Contents 

Byte 

ffset 

O

Name 

Format 

Scaling  Units  Description 

calibrationRequest 

U2 

— 

— 

The requested calibration task 

 
Currently, magnetic alignment is the only function supported by the calibrate command.  There are two magnetic 
alignment procedures supported; (1) magnetic alignment with automatic yaw tracking termination, and magnetic 

alignment without automatic termination.   

Table 26  Magnetic Alignment 

calibrationRequest 

Description 

0x0009 

Begin magnetic alignment without automatic termination.   
Rotate vehicle through >360 degrees yaw and then send 0x000B 

calibration request for termination. 

0x000B 

Terminate magnetic alignment.  The unit will send a CC respons
containing the hard‐iron and soft‐iron values.   

To accept the parameters, store them using the write magnetic 
calibration command.   

0x000C 

Begin magnetic calibration with automatic termination.  Rotate the unit
through 380 degrees in yaw.   

oft‐iron 

 

The unit will send a CC response containing the hard‐iron and s
values upon completion of the turn.   
To accept the parameters, store them using the write magnetic 