Comm LED Operation

The Comm LED - located on the upper enclosure connector panel - indicates system control status. This can be used
determine if the luminaire is receiving a control signal. LED indications are as follows:

Figure 2-12: Comm LED

+

Green - The Comm LED will light

green

if either DMX or Ethernet control is present. Note that if both valid DMX

and Ethernet control are being received, DMX control will take precedence.

+

Red - The Comm LED will light

red

if no DMX or Ethernet is present.

Bypassing Calibration

If the menu screen is touched (in the center) and held during startup, the luminaire will
present a menu that provides the option to bypass calibration. This feature allows the
luminaire to skip the calibration sequence so that it can be powered up in the case for
configuration purposes.

To bypass calibration:

Step

1. Connect power to luminaire.

Step

2. At startup, touch center of menu screen and hold until Bypass Calibration

menu appears.

Step

3. Press

Yes

to bypass calibration. (The menu will automatically dismiss if no

selection is made within 5 seconds.)

Step

4. Proceed with programming of starting address or other options.