52

BAD BOY

®

SPOT LUMINAIRE USER MANUAL

TROUBLESHOOTING

Troubleshooting Guide

The following table provides a list of common start-up problems and possible solutions.

Symptom

Solution(s)

Refer to...

No power to luminaire.

Ensure power cable is properly connected to Neutrik
input connector.

page 14

Ensure power is switched on at source (mains,
disconnect box, etc.)

n/a

No console control.

Ensure DMX512 or Ethernet data cable is properly
connected.

page 23

Ensure DMX512 address setting is correct.

page 27

DMX512 control not working
correctly throughout daisy-chain.

Ensure data cables are correctly configured.

page 23

Ensure termination connector is installed at last
luminaire in data link.

page 16

Lamp does not strike at power-up.

Configure lamp to start at power-up.

page 38

Comm LED is red indicating that no
valid DMX or Ethernet signal is
detected.

Ensure DMX512 or Ethernet data cable is properly
connected.

Check console.

page 23

No Ethernet control.

Ensure that luminaire is not also receiving a DMX
signal. If both valid DMX and Ethernet control are
being received, DMX control will take precedence.

page 26

Beam obstructed by gobo in open
position.

Set new gobo zero position.

page 50

Luminaire won’t take software
update.

Remove active control (DMX512 or Art-Net).

page 60