Troubleshooting

+

If the LumLoader application does not start up, make sure the Java library is installed.

+

Make sure the network port is active before starting the application. Sometimes it takes several seconds for the
operating system to recognize the network link.

+

Make sure there is only one instance of the LumLoader application running.

+

Wireless should be disabled on the computer.

Software Crossload

The Information menu provides a method for sending a
luminaire’s current software version to all connected luminaires.
(Luminaires can be daisy-chained via DMX512 or Ethernet.)

To initiate the software crossload, press "Crossload SW" at the
Information screen. At confirmation screen, press "Yes." If a
connected luminaire already has that software version, it will do
nothing. If it does not have the same version, it will go into the
boot screen and start updating.

Note: There should be no active control (DMX512 or Art-Net)
during the update process.

Press INFO to
bring up Info screen

Press Crossload SW to
bring up confirmation