PRG Bad Boy User Manual 1.6 User Manual

Page 63

Advertising
background image

BAD BOY

®

SPOT LUMINAIRE USER MANUAL

55

Other Errors

Error Code

Explanation

Solution

Temp over threshold

Temperature too high

Check fans/filters

Lamp over threshold

Lamp hours above recommended
maximum

Change lamp

Lamp Off

Fan Error: Cannot strike lamp while
any fan is in error state

Check fan, fan cabling

Pan/Tilt Aux Encoder Error

Auxiliary encoder value is too far
from the main encoder value

Check auxiliary encoder and
cabling/connections

Gobo out of zero range

When zeroing gobo wheels, the
wheel is too far away from zero to
set the position

Move wheel closer to home position
before zero command

DMX busy: cancel
crossload

Cannot execute crossload with
traffic on DMX line

Remove incoming DMX control for
cross load

Data not crossload format

Data in memory is not proper format
for crossload

Load software via computer

DMX: UART transmit error

Transmit buffer busy when trying to
send

Remove any incoming DMX, retry

Crossload Timeout

Crossload execution took too long
due to error

Remove any incoming DMX, retry

CAN Comm Error

Stopped receiving CAN messages
from motion processor

Check CAN cables/connections,
motor control board

Main Fan Error

Main fan CAN messages not
received or fan not running properly

Check fan, fan cabling

UPE Fans Error

Upper Enclosure fans not running
properly

Check fan, fan cabling

Pinch Fan Error

Pinch fan not running properly

Check fan, fan cabling

Stack Fan Error

One or more stack fans not running
properly

Check fan, fan cabling

Advertising