Cleaning the head electrostatic filters – PRG Bad Boy User Manual 1.6 User Manual

Page 73

Advertising
background image

BAD BOY

®

SPOT LUMINAIRE USER MANUAL

65

Cleaning the Head Electrostatic Filters

The electrostatic filters should be cleaned or replaced when they are dirty. The frequency will depend on how often
and in what conditions the luminaire is used.

Tools:

#2 Phillips screwdriver
Compressed air

and/or

water

To clean head filters:

WARNING:

Remove power from luminaire before performing any maintenance procedures.

Step

1. Remove power from luminaire.

Step

2. At each mesh cover, loosen one captive screw (Figure 4-4).

Step

3. Remove foam and electrostatic filters.

Step

4. Clean foam and electrostatic filters with compressed air and/or by washing with water.

Step

5. Re-install components.

Step

6. Repeat for second set of filters.

Figure 4-4: Removing Head Filters

Parts:

10.9812.0661

2 EA

HEAD AIR FILTER FOAM

10.9812.0662

2 EA

HEAD AIR FILTER ELECTROSTATIC

Foam Filter

Electrostatic Filter

Mesh Cover

Captive Screw

NOTE:
If the filters do not get clean after multiple
attempts, they should be replaced.

Advertising