Technical specifications 1.0, Danger – Proheat M125 User Manual
Page 14
M50 12V
M50 24V
M80 12V
M80 24V
M90 24V
M105 24V
M125 24V
RATING BTU/hr (kW)
50,000
50,000
80,000
80,000
90,000
105,000
125,000
(15)
(15)
(23)
(23)
(26)
(31)
(37)
SYSTEM VOLTAGE
12
24
12
24
24
24
24
Nominal DC Voltage (Range)
(10–15)
(20–30)
(10–15)
(20–30)
(20–30)
(20–30)
(20–30)
CURRENT DRAW (MAX) Amps
9.5
5.2
8.5
5.2
5.2
9.5
9.5
FUEL CONSUMPTION US gal/hr (L/hr)
0.48
0.48
0.78
0.78
0.82
1.05
1.10
(1.8)
(1.8)
(2.95)
(2.95)
(3.10)
(3.97)
(4.16)
IGNITION TYPE
Electronic Spark Ignition
COOLANT OUTPUT TEMPERATURE MAX.
185°F (85°C)
AMBIENT OPERATING TEMPERATURE
-40°F to +122°F (-40°C to +50°C)
WEIGHT lbs (kg)
53 (24)
57.5 (26.1)
60 (27.2)
HEAT EXCHANGER CAPACITY US gal (l)
0.5 (2)
0.6 (2.3)
0.7 (2.6)
COOLANT SYSTEM
Minimum Capacity/Recommended Flow
Rate Through Heater US gpm (lpm)
7.5 (28)
7.5 (28)
12 (45)
12 (45)
13.2 (50)
15.8 (60)
18 (68)
Maximum Coolant Pressure PSI (bar)
29 (2)
29 (2)
29 (2)
29 (2)
29 (2)
29 (2)
29 (2)
SYSTEM INPUTS
SWITCH
Same as Power Supply Voltage
Standard Run Mode
Preheat Run Mode
Supplemental Run Mode
COOLANT PUMP
Same as Power Supply Voltage
AUXILIARY
Allows independent operation of Coolant Pump through
the G-II Proheat Control Module
POWER
12 Volt or 24 Volt
PROHEAT M-SERIES G-II PCM SERVICE MANUAL
1-1
TECHNICAL
SPECIFICATIONS
1.0
SYSTEM OUTPUTS
AUXILIARY OUTPUT
Same as Power Supply Voltage
Maximum 1 Amp draw (over-load shut-off protection)
High-side switched
SWITCH/TIMER
Same as Power Supply Voltage
POWER
Maximum 1 Amp draw (over-load shut-off protection)
High-side switched
COOLANT PUMP
Same as Power Supply Voltage
Maximum 10 Amp draw (over-load shut-off protection)
High-side switched
INDICATOR LIGHT
Same as Power Supply Voltage
Maximum 1 Amp draw (over-load shut-off protection)
High-side switched
DANGER
Do not use gasoline.
FUEL TYPES
COMPATIBLE
Diesel (ULSD, #1, #2, Arctic), JP8, Jet A1
Bio Fuels - Contact Proheat www.proheat.com