EXHAUST
(SEE NOTE 2 AND 4)

-4 JIC MALE FUEL INLET (INTERNAL
FUEL FILTER) (SEE NOTE 5)

2.75 (70)

12.60 (320)

25.74 (654)

5.37

(136)

8.14 (207)

2.03 (52)

FRONT VIEW

2 x .394 (10)

BOTTOM VIEW

AIR INTAKE
ALTERNATE
SNORKELS
AVAILABLE
(SEE PAGE 1-3 )

3.22

(82)

5.00 (27)

3.98

(101)

SIDE VIEW

SERVICE SPACE REQUIREMENT
(MAY VARY SEE NOTE 3 & PAGE 1-3)

G-II

PCM

5.39

(137)

9.5

(241)

8.55

(217)

REAR VIEW

4.33

(110)

4.33

(110)

5.91

(150)

.394

(10)

3 x M8 x 1.25

HEAT EXCHANGER
(SEE NOTE 6)

10.13 (257)

9.00 (229)

8.25

(210)

DUAL MODE TEMPERATURE
SENSOR

12.05 (306)

TOP VIEW

COOLANT INLET

COOLANT OUTLET

2 x 1.50 (38)

1.97 (50)

1. DIMENSIONS ARE IN INCHES (MILLIMETERS IN BRACKETS).

2. TYPICAL EXHAUST CUTOUT 3.25" CENTERED ON EXHAUST.

3. SERVICE SPACE REQUIRED TO REMOVE BURNER HEAD AND

COMBUSTION TUBE FOR PERIODIC INSPECTION AND CLEANING.

4. THE EXHAUST PIPE SHOULD HAVE A MINIMUM DIAMETER OF

2.75", A MAXIMUM LENGTH OF 5' AND HAVE NO MORE THAN
180° OF BENDS.

5. ALTERNATE FUEL INLET CONFIGURATIONS AVAILABLE, SEE

PARTS BOOK FOR FURTHER INFORMATION.

6. ALTERNATE HEAT EXCHANGERS AVAILABLE, SEE PARTS BOOK

FOR FURTHER INFORMATION.

7. SNORKEL HOSE REQUIRED FOR THIS AIR INTAKE OPTION.

CONTACT TECH SUPPORT AT WWW.PROHEAT.COM FOR
LENGTH AND BEND RESTRICTIONS.