4.1.15

(14 Flashes)

ACCESSORY/SWITCH OUTPUT Diagnostic Code 14

Indicates a short circuit fault in the harness or the device being operated by

the Switch Output.

Troubleshoot the Switch/Timer Power diagnostic code based on:

Electrical switch circuit in the switch wiring.

Test procedure electrical, short circuit:

a)

Remove the Switch Output harness at the G-II PCM.

b)

Remote start the PROHEAT using the PROHEAT remote start switch

(PROHEAT P/N PK0091).

If the PROHEAT functions correctly, the fault is in the wiring from the

PROHEAT back to the switch. See OEM recommended service requirements.

If the PROHEAT does not function, the G-II PCM is faulty. Go to G-II PCM

replacement, page 4-38.

AUXILIARY OUTPUT Diagnostic Code 13

Indicates a short circuit fault in the harness or the device being operated by

the Auxiliary Output.

Troubleshoot the Auxiliary Output diagnostic code based on:

G-II PCM – electrical

Test procedure – G-II PCM Output Signal:

a)

Disconnect the Auxiliary Output harness at the G-II PCM.

b)

Switch the PROHEAT on and operate for at least one complete cycle.

Observe the operation.

If the diagnostic code is not indicated the fault is in the harness or the

driven device. Go to OEM for service requirements.

If the diagnostic code is still indicated, the G-II PCM is faulty. Go to G-II

PCM replacement, page 4-38.

Figure 4-36: Auxiliary Output Connector.

G-II PCM AUXILIARY
OUTPUT CONNECTION

4.1.14

(13 Flashes)

NOTICE

All plugs/harnesses must be rein-

stalled into the G-II Proheat Control

Module (G-II PCM) before heater

goes back into service.

NOTICE

Depending on the G-II PCM part no.

the Auxiliary Mode output operates

in one of 4 following modes:

Normal: Auxiliary output is only on

when the heater is switched on.

Indicator: Auxiliary output behaves

exactly the same as the G-II PCM

indicator light.

Flame: Auxiliary output is only on

when the flame is on.

Preheat: Auxiliary output is only on

during Preheat mode.

Please refer to the M-Series Parts Book

at www.proheat.com for part numbers.

NOTICE

All plugs/harnesses must be rein-

stalled into the G-II Proheat Control

Module (G-II PCM) before heater

goes back into service.

4-34