Indicator output diagnostic code 15, Motor speed sensor diagnostic code 17, Canbus error diagnostic code 18 – Proheat M125 User Manual

Page 72: System current diagnostic code 16

Advertising
background image

4-35

PROHEAT M-SERIES G-II PCM SERVICE MANUAL

4.1.16

(15 Flashes)

INDICATOR OUTPUT Diagnostic Code 15

Indicates a short circuit fault (current draw greater than 1 Amp) in the harness

or the device being operated by the Indicator Output.

Troubleshoot the Indicator Output diagnostic code based on:

Electrical indicator output circuit in the switch wiring.

Test Procedure – Electrical, short circuit:

a)

Remove the existing switch harness at the G-II PCM.

b)

Remote start the PROHEAT using the PROHEAT remote start switch

(PROHEAT P/N PK0091).

If the PROHEAT functions correctly, the fault is in the wiring from the

PROHEAT back to the switch indicator light. See OEM recommended

service requirements.

If the INDICATOR OUTPUT Diagnostic Code 15 is still indicated, the G-II

PCM is faulty. Go to G-II PCM replacement, page 4-38.

4.1.18

(17 Flashes)

MOTOR SPEED SENSOR Diagnostic Code 17

Indicates the motor RPM signal has not been detected for 5 seconds while

normal (less than 12 Amps) current is flowing through the motor.

Troubleshoot the Motor Speed Sensor code based on:

a)

Inspect the Combustion Air Blower magnet for damage.

b)

Motor mechanical function. Go to page 4-32 and perform

Test Procedure – Motor mechanical function.

If the Motor Speed Sensor Diagnostic Code 15 is still indicated, the G-II

PCM is faulty. Go to G-II PCM replacement, page 4-38.

4.1.19

(18 Flashes)

CANbus ERROR Diagnostic Code 18

Indicates the heater was switched on via a CANbus input and then lost the

CANbus heartbeat message for longer than 5 seconds.

The heater will go to the cool down (purge) mode then turn off until valid CAN

communication is restored.

If the Diagnostic Code 18 is still indicated please contact Proheat for further

information.

4.1.17

(16 Flashes)

SYSTEM CURRENT Diagnostic Code 16

Indicates the total system current limit of 25 Amps was reached as measured

by the G-II PCM.

NOTE In an attempt to lower the system current, the auxiliary output is turned

off for the remainder of the current cycle.

Troubleshoot the System Current diagnostic code based on voltage: page 4-26.

Advertising
This manual is related to the following products: