4.1

SYSTEM AND COMPONENT
DIAGNOSTICS

The G-II PCM continually monitors the PROHEAT operating conditions. If the G-II

PCM detects a problem, the indicator light flashes a diagnostic code(s) on

the G-II PCM status LED.

The diagnostic indicator light may also be located:

In the toggle of the ON/OFF Switch provided by PROHEAT (standard

installation kit).

In the PROHEAT Timer manual ON light (red).

In an OEM indicator light package.

In the remote switch (PROHEAT P/N PK0091) used for troubleshooting.

It is possible to have one or more diagnostic codes displayed. Codes are displayed

by a series of short flashes (that corresponds to the number of the Diagnostic

code) then turned off for 2 seconds and then the next code is displayed.

Note: The Same code is displayed only if one diagnostic code is active.

For example if a 7 and 10 Diagnostic Code occurs together, the G-II PCM status

light will flash Red 7 times then pause for 2 seconds then flash Red 10 times.

Similarly the remote ON/OFF Switch, Timer red manual light (T-II Timer will also

display the code on LCD) or OEM indicator light (installation options) will flash 7

times, pause and then 10 times.

G-II PCM STATIUS

STATE

LIGHT COLOUR

GREEN

Flash Twice

Power Up.When power is first applied

(fast) then off

to the G-II PCM the Green LED will

flash (fast) twice to indicate that the

G-II PCM has booted up.

GREEN

On Solid

Heater is switched on Via analog

switch inputs and is operating

normally

GREEN

Off then two

Heater is connected to CANBus

flashes then

network and is communicating on the

off again

network but is not switched on

GREEN

On Solid with

Heater is switched on Via Analog or

two flashes then

CANBus switch inputs and is operating

on solid again

normally and communicating on the

network

RED

On Solid

Software problem detected. Contact

Proheat for further information.

RED

Flashing

Diagnostic Blink Code(s)

Flashing alternating

Flashing

Data Link cable incorrectly installed.

RED then GREEN

Remove the data cable and power

from G-II PCM for 20 seconds. Then

re-apply power first, and then connect

the data cable.

ORANGE

On Solid for up

Motor is locked up or frozen

to 60 seconds