Proheat M125 User Manual

Page 16

Advertising
background image

PROHEAT M-SERIES G-II PCM SERVICE MANUAL

1-3

AIR INTAKE OPTION:

3" OD SNORKEL SEE NOTE 7

AIR INTAKE OPTION:

2.25" OD ELBOW WITH 26° ADAPTER PLATE

SEE NOTE 7

CAN BE INSTALLED AT: 26°, 116°, 206°, 296°

AIR INTAKE OPTION:

2.25" OD SNORKEL SEE NOTE 7

AIR INTAKE OPTION: 2.25" OD ELBOW SEE NOTE 7

CAN BE INSTALLED AT 0°, 90°, 180°, 270°

24.31 (617

)

4.71

(120

)

SERVICE

SPACE

REQUIREMENT

(SEE NOTE 3)

9.21

(

234)

29.09 (637

)

3.93

(100

)

SERVICE

SPACE

REQUIREMENT

(SEE NOTE 3)

9.99

(

254)

24.00 (610

)

5.20

(132

)

SERVICE

SPACE

REQUIREMENT

(SEE NOTE 3)

8.90

(

226)

24.80 (630)

4.22

(107)

SERVICE

SPACE

REQUIREMENT

(SEE NOTE 3)

9.70 (246)

90°

270°

180°

116°

26°

296°

206°

1. DIMENSIONS ARE IN INCHES (MILLIMETERS IN BRACKETS).

2. TYPICAL EXHAUST CUTOUT 3.25" CENTERED ON EXHAUST.

3. SERVICE SPACE REQUIRED TO REMOVE BURNER HEAD AND

COMBUSTION TUBE FOR PERIODIC INSPECTION AND CLEANING.

4. THE EXHAUST PIPE SHOULD HAVE A MINIMUM DIAMETER OF

2.75", A MAXIMUM LENGTH OF 5' AND HAVE NO MORE THAN
180° OF BENDS.

5. ALTERNATE FUEL INLET CONFIGURATIONS AVAILABLE, SEE

PARTS BOOK FOR FURTHER INFORMATION.

6. ALTERNATE HEAT EXCHANGERS AVAILABLE, SEE PARTS BOOK

FOR FURTHER INFORMATION.

7. SNORKEL HOSE REQUIRED FOR THIS AIR INTAKE OPTION.

CONTACT TECH SUPPORT AT WWW.PROHEAT.COM FOR
LENGTH AND BEND RESTRICTIONS.

NOTES:

Advertising
This manual is related to the following products: