VOLTAGE: Step 2

(5 Flashes)

VOLTAGE Diagnostic Code 5

Indicates that the supply voltage to the G-II PCM is outside the operating

range for more then 10 seconds.

Operating Range:

12 volt PROHEAT – 10 to 16 volts.

24 volt PROHEAT – 18 to 32 volts.

Troubleshoot the Voltage diagnostic code based on:

1.

Low voltage.

Voltage supply is below the rated requirement.

Poor or faulty electrical connections.

Voltage supply source is OK. Voltage drop due to high amperage load

while the PROHEAT is operating or trying to operate.

2.

High voltage.

Voltage supply is above the rated requirement while the vehicle

engine is running.

High Voltage – Check:

The vehicle charging system. Consult the OEM for service requirements.

Low Voltage – Check:

a)

System voltage supply source.

b)

Wiring harnesses and connection points.

Procedure – Low voltage testing:

a)

Inspect the wiring harnesses and connections for corrosion and proper

fit. Clean if necessary.

b)

Using a multimeter set for voltage, measure across the positive and

negative battery terminals or at the supply source.

If the voltage is below the required voltage, service the batteries and/or

charging system as per OEM supplier recommendations.

If the voltage level is within the operating range, go to item 'c'.

4.1.6

(5 Flashes)

VOLTAGE: Step 1

(5 Flashes)

Figure 4-27: Voltage Measurement.

TO PROHEAT

4-26

PROHEAT M-SERIES G-II PCM SERVICE MANUAL