Scenario 1 Set Output Relays

Select Detector Interface and Route Relays:
1)
Click the Detector Interface button to select
the type of detector/controller interface to be used
( Type-170 ).
2) Click the Ph- button to select Phase group 1L.
Note that the line zones corresponding to the
selected phase group turn green. All others are
magenta.
3) Click the RI/Card= button to select the
number of relays per card = 4 .
4) After selecting the RI/Card=4, the number of
card edge relays (F,W,etc.) that are shown changes
corresponding to this selection.
5) Click the Ext= and the Dly= to select the
Detection Extension in seconds and the Detection
Delay in seconds.
6) Click N, Or, And button to select logic for
combining (N=Not Used) Phase Groups into Card
Edge Relays.
7) To clear the settings for the selected Phase
group or for all Phase groups click the Clear or the
Clear All button.

6

1

2

3

4

7

5

Type-170 Detector/Controller Interface with 4 Relays per SVS-1 card and 3 Phases (Line Zone Groups)

Phase 1L, Detection Delay=0 sec, Detection Extension=0, Route to Card Edge F

Phase 6T, Detection Delay=0 sec, Detection Extension=0, Route to Card Edge W
Phase 6R, Detection Delay=2 sec, Detection Extension=0, Route to Card Edge W

Specifies Routing to Onboard Output Relay
Connector (1, 2, .., 10 0-Disables) for shelf
mount SVS-1