SmarTek Systems SVS-1 User Guide-Part B User Manual

Page 35

Advertising
background image

Routing/Mapping Each Phase to an On Board Connector Relay Position

The three columns at the center of the window are used to set the Detection Extension (seconds) and the Detection Delay (seconds) for
each Phase, and the mapping or routing of each Phase to an output relay position of the Green On Board Connector on the shelf mount
SVS-1 rear panel. This connector has 10 output relays and can be used when no external relay interface (cards in a card file or
BIU/SDLC) is used.

The OB connector applies only to the shelf mount SVS-1.

1) Click the “Clear All Detector Routing Check Boxes” button to clear all of the right side

routing check boxes.

2) Click in each OB Relay Connector field to select the output relay position. More than one Phase

can be mapped/routed to the same On Board Connector output relay position (0 disables).

3) The example shown routes Phase-1L to position 1, Phase-6T to position 2, and Phase-6R to position 3

of the On Board green connector.

4) Note that a Phase from any active SVS-1 camera channel (SVS0001, SVS0002, etc.)

can also be routed to a relay position in the On Board Connector.