Routing Each Phase to a BIU Detector Channel Using SVS Relay Interface Cards

1) Click the Clear All Detector Routing Check Boxes button to clear all of the right side routing check
boxes. Click the Detector Interface field to select BIU# 1-CardFile.
2) Click in the Relays per SVS-RI Card field to select the number of relays per card.
3) Click in the Det Main/Aux SVS-RI Slot # fields to select the card file slots to use.
4)

Note that choosing the RL card slot position, sets the Detector Channels available (column header labels

D1, D2, etc.) for use (per the TS-2 Specification).

5) Click each routing check box (right side check boxes) to specify which Phases will be combined (Or’ed or
And’ed) and routed to each Detector Channel. For this example, Phase-1L is routed to Detector Channel 1
(D1), Phase-6T is routed to D2, and Phase-6R has a Detection Delay of 5 seconds and is also routed (Or’ed)
to D2. Note: Only the Main SVS Relay Interface card is used.