Dip switch, Table 4-3 faceplate serial port selection – ADLINK aTCA-N700 User Manual
Page 19
aTCA-N700 HW Users Guide
19
Table 4-1 Shelf Manager Interoperability Mode Setting: J25
Operating Mode
Condition
Stand-alone mode
Closed
Shelf mode
Open
4) Hot swap switch selector Header (J4): The Header can select SW6 or SW3
Hot swap switch close Header (J2): If Pin 1 and 2 of J2 are closed, it is the same as
the closed Hot swap switch.
Table 4-2 Shelf Manager Interoperability Mode Setting: SW3, SW6
Switch
Condition
SW3
Pin1, 2 Closed, Pin3 Open
SW6
Pin 2,3 Closed, Pin1 Open
Note: SW6 is recommended.
4.1.2. DIP Switch
1) SW2:
The faceplate serial port is set for the LMP console as a default. For testing purposes,
the serial port can be configured to connect to the IPMC console as depicted in the
following table.
Table 4-3 Faceplate serial port selection
SW NO
Mode
Setting
Figure
LMP Console
1 ON
2 ON
3 OFF
4 OFF
SW2
IPMC
Debug Console
1 OFF
2 OFF
3 ON
4 ON