Table 9-14 threshold values: temperature – ADLINK aTCA-N700 User Manual
Page 70
Advertising
aTCA-N700 HW Users Guide
70
ATCA-N700
+0.75V_NPA_B
UNR : +1.35V
UC : +1.02V
UNC : +0.7875V
LNC : +0.6625V
LC : +0.65V
LNR : +0.15V
0.01V
ATCA-N700
+0.75V_NPB_A
UNR : +1.35V
UC : +1.02V
UNC : +0.7875V
LNC : +0.6625V
LC : +0.65V
LNR : +0.15V
0.01V
ATCA-N700
+0.75V_NPB_B
UNR : +1.35V
UC : +1.02V
UNC : +0.7875V
LNC : +0.6625V
LC : +0.65V
LNR : +0.15V
0.01V
Table 9-14 Threshold Values: Temperature
Title
Thresholds(Tmax = Tj)
Hysteresis
ATCA-N700 NPA
Temp
UNR : 111℃
UC : 101℃
UNC : 91℃
2℃
ATCA-N700 NPB
Temp
UNR : 111℃
UC : 101℃
UNC : 91℃
2℃
ATCA-N700 SWT
Temp
UNR :120℃
UC : 110℃
UNC : 100℃
2℃
ATCA-N700 LMP
Temp
UNR :115℃
UC : 105℃
UNC : 95℃
2℃
Advertising